Accessible waiting room

The access provisions of Premises Standards 2010 have been incorporated into NCC Volume 1 BCA, effective from 1 May 2011.

In all public buildings, access is required to and within all areas normally used by the occupants. Fit-out criteria for these spaces are not included in the BCA. Uninformed design of fit-out can render a space inaccessible, despite its compliance with the BCA access provisions . Inaccessible buildings and spaces are at risk to complaint under the DDAct.


Accessible waiting room

1. APPLICATION

Where a waiting room is provided it should be accessible.

2. DESIGN CONSIDERATIONS

This Design Guide contains criteria for elements which are beyond the scope of the NCC and the Premises Standards.  As far as possible it does not repeat the mandatory requirements of the NCC.

Circulation space

Provide circulation spaces to meet AS1428.1 around all furniture. 

Waiting space

Provide adequate space for the number of persons using the premises to be able to sit, park their walking frames, perambulators or wait in their wheelchairs without obstructing access for others.

Seating

Provide seats and seating spaces for all customers/clients if waiting times are likely to be more than 10 minutes.

Space chairs 200mm clear of each other.

Select ergonomically designed chairs with backrests and arms. Seat height of 450mm is generally suitable but heights of up to 520mm are preferred where a high proportion of elderly users is anticipated. Children and small people may, however, require seats as low as 350mm. Otherwise select seating to meet AS/NZS4688.2, 4688.3 and 4688.4 and AS1428.2.

Provide armrests to most seats. Armrests assist persons who are frail or have ambulant disability in getting in and out of the seat. Bench-type seating with armrests at the ends accommodate people of varying sizes.

Provide some bariatric seats with a seating space of 700mm-wide x 450mm-deep per person.

Wheelchair space

Provide at least one wheelchair seating space. In larger waiting rooms allocate at least 10% of the number of seating spaces for wheelchairs, walking frames and perambulators, with a greater percentage in waiting rooms of premises providing services for children, health care or for a large number of wheelchair users.

Allow for groups of two-wheelchair seating spaces between groups/rows of regular seats. A location at the end of a row of regular seats is suited for a single- wheelchair seating space. Such arrangement will enable two related wheelchair users to sit together or individual wheelchair users to sit next to their companion sitting in the regular seat.

Allow 850mm wide x 1300mm deep space for one wheelchair, 1700mm wide x 1300mm deep space for two wheelchairs, plus 1200mm wide circulation space in front of all wheelchair spaces.

Reception counter

See Accessible reception counter .

Shelving for reading matter

  • For side reach - 1350mm max high
  • For forward reach - 1120mm max high

Furniture and fittings

Select and/or detail drinking fountains, chilled and boiling water dispensers, coffee or tea making machines, vending machines, taxi phone, public telephone, ATM for access by wheelchair users. Meet AS1428.2-1992 Clause 22 for reach ranges and AS1428.1-2009 Figure 45 for location of controls and knee/toe clearance under fittings.

See Drinking fountains and Accessible tea point.

Other features

Consider provision of a hearing-augmentation system at reception and information counters to assist communication with a person with a hearing impairment where the customer is not screened from the service provider.

The SoundShuttle, for example, is a free-standing unit with built-in induction loop and microphone that is now widely used at such reception and information counters. Provision of a hearing-augmentation system is mandatory when the customer is screened from the service provider.

Avoid screening wherever possible.

Provide glare free illumination of minimum 200 lux.

Ensure 30% minimum luminance contrast against the background for all fittings and controls.

Provide directional signage if toilets and other facilities are not immediately apparent from the waiting room.

3. REFERENCES

AS1428.1 – 2009 (Incorporating amendment No. 1 - 2010)

Design for Access and Mobility Part 1: General Requirements for Access—New Building Work

AS1428.2 – 1992

Design for Access and Mobility Part 2: Enhanced and Additional Requirements—Buildings and Facilities.

Disclaimer

This content is provided by the Australian Institute of Architects for reference purposes and as general guidance. It does not take into account specific circumstances and should not be relied on in that way. It is not legal, financial, insurance, or other advice and you should seek independent verification or advice before relying on this content in circumstances where loss or damage may result. The Institute endeavours to publish content that is accurate at the time it is published, but does not accept responsibility for content that may or has become inaccurate over time. Using this website and content is subject to the Acumen User Licence.

Was this note helpful?

We are always looking to improve our content and your opinion is important to us. If you have any feedback or suggestions on how this article could be more relevant and useful, please outline below.

Recently Viewed

Business continuity and disaster planning
Practice
24 January 2024
QUT Peter Coaldrake Education Precinct
Environment
7 December 2022
Life cycle assessment (LCA)
Environment
17 December 2018
Ecological connectivity design strategies
Environment
29 November 2023
Partition system acoustics
Project
30 November 2011